No Touch Steamhead: (NTSC-XX, NTST-XX, NTSM-XX, NTSR-XX)
The Steamhead should be mounted at least 12" from the floor or bathtub and 6" from any corner. The steamhead is to be mounted as far as possible from typical bathing position (seated or standing) and as far as possible while maintaining a 60" control height.
SteamVection: (SVRD-XX, SVSQ-XX)
The Steamhead should be mounted at least 24" from the floor or bathtub and 6" from any corner. The steamhead is to be mounted as far as possible from typical bathing position (seated or standing) and as far as possible while maintaining a 60" control height.
WARNING: STEAM IS HOT! DO NOT TOUCH OR GO NEAR THE STEAMHEAD FROM THE TIME THE UNIT IS "ON", UP TO ONE HOUR AFTER IT HAS SHUT OFF. SEVERE BURN WILL OCCUR IF YOU COME IN CONTACT WITH THE STEAMHEAD OR STEAM EMITTING FROM THE STEAMHEAD.
For more detailed information go to Installing Steamhead and Steam Line